Smartphone Camera Measurement of Breathing-Related Heart Rate Variability Compared With ECG in Healthy Adults
StatusNot Yet Recruiting
PhaseNot applicable
SponsorBELL Therapeutics Inc.
Primary completion (estimated)
Track this trial
Free. We email you which fields changed when ClinicalTrials.gov updates this record.
Record History
All 1 version: 1 with changes below.
- Study First Submitted
Endpoints
Primary
Log Ratio of Facial Remote Photoplethysmography to ECG Respiratory Heart Rate Variability Amplitude During Slow Paced Breathing
Timeframe: Seven slow paced-breathing conditions (3 minutes each; 6.0 breaths/min 5 minutes) during a single study visit (Day 1)
Secondary (16)
Log Ratio of Fingertip Contact Photoplethysmography to ECG Respiratory Heart Rate Variability Amplitude During Slow Paced Breathing
Within-Participant Difference Between Facial-to-ECG and Fingertip-to-ECG Absolute Log Ratios of Respiratory Heart Rate Variability Amplitude During Slow Paced Breathing
Percentage of Attempted Conditions Without a Valid Facial Estimate
Percentage of Attempted Conditions Without a Valid Fingertip Estimate
Percentage of ECG Beats Without a Matching Facial Pulse Beat (Missed Beats)
Show 11 moreShow less
Percentage of ECG Beats Without a Matching Fingertip Pulse Beat (Missed Beats)
Percentage of Facial Pulse Beats Without a Matching ECG Beat (Extra Beats)
Percentage of Fingertip Pulse Beats Without a Matching ECG Beat (Extra Beats)
Log Ratio of Facial to ECG Root Mean Square of Successive Differences (RMSSD) During Free Breathing
Log Ratio of Fingertip to ECG Root Mean Square of Successive Differences (RMSSD) During Free Breathing
Log Ratio of Facial to ECG Standard Deviation of Normal-to-Normal Intervals (SDNN) During Free Breathing
Log Ratio of Fingertip to ECG Standard Deviation of Normal-to-Normal Intervals (SDNN) During Free Breathing
Log Ratio of Facial to ECG Respiratory Heart Rate Variability Amplitude at 15 Breaths/Min
Log Ratio of Fingertip to ECG Respiratory Heart Rate Variability Amplitude at 15 Breaths/Min
Log Ratio of Facial to ECG Respiratory Heart Rate Variability Amplitude With a Shorter Settling Period or Shorter Recording (Exploratory)
Log Ratio of Facial to ECG Respiratory Heart Rate Variability Amplitude at 6.0 Breaths/Min: 3-Minute and 5-Minute Windows
Arms and interventions
Smartphone and Reference Measurement During Free and Paced BreathingExperimental
Single group. Each participant completes free breathing (5 min), then paced breathing at 4.0, 4.5, 5.0, 5.5, 6.5 and 7.0 breaths/min (3 min each) and 6.0 breaths/min (5 min) in randomized order, and finally paced breathing at 15 breaths/min (3 min), with 2-minute rests. Throughout each condition the face and fingertip are measured simultaneously by one smartphone, while a chest ECG and a respiratory belt record continuously as references.
Devices: Smartphone simultaneous facial and fingertip photoplethysmography (research app)
Behavioral: Audio-guided paced breathing