Towards a More Standardized Bicuspid Aortic Valve Repair: Rationale and Design of CONTOUR Trial - a Randomized Trial

Study acronym: CONTOUR
StatusRecruiting
PhaseNot applicable
Started
View on ClinicalTrials.gov ↗

Record History

See every version on ClinicalTrials.gov ↗

  1. Notable Trial status: Not Yet Recruiting to Recruitingv2 Show 4 more changesShow less
    • Study sites: 0 to 4
    • Start date changed from estimate of Apr 2025 to May 21, 2025
    • Secondary endpoints: details revised at 1 of 10 entries
    • Study title expanded, about 4 words
  2. Minor Study First Submitted
  • Stopped: an ongoing trial was terminated, suspended or withdrawn.
  • Notable: the trial’s plan changed such as a big move in its timeline or size, a new primary endpoint, sponsor or phase, or recruiting opened or resumed.
  • Minor: routine progress and housekeeping, such as sites added or enrollment closed.
Background: Between one-third and one-half of patients with bicuspid aortic valve (BAV) disease develop significant aortic regurgitation (AR) at a young age, leading to cardiomyopathy and heart failure. Aortic valve repair is an evolving and still underused strategy in BAV patients with AR. The lack of sufficient standardization remains the main limitation of current repair techniques, resulting in an increased risk of AR recurrence and reoperation. The most controversial issue is the stabilization of the BAV annulus. The CONTOUR trial aims to compare two different BAV annuloplasty concepts in a prospective randomized study. Methods: CONTOUR is a multicenter, randomized controlled trial designed to enroll 100 consecutive BAV patients with AR across four sites in Germany. BAV AR patients with an asymmetric configuration and without concomitant root aneurysm will be randomized 1:1 to undergo aortic valve repair using an internal HAART 200 annuloplasty device (i.e., INTERNAL group) (n=50) or external annuloplasty (i.e., double external ring annuloplasty) in the EXTERNAL group (n=50). 4D flow MRI will be performed preoperatively (t1), postoperatively at discharge (t2), and at 1-year follow-up (t3) for rater-blinded assessment of hemodynamic profiles (i.e., flow eccentricity) and regurgitation fraction at the MRI core-lab. Two hierarchically ordered primary endpoints will be considered: (1) postoperative reduction of flow eccentricity at hospital discharge and (2) regurgitation fraction (%) at 1-year follow-up. Discussion: The CONTOUR trial is designed to test the hypothesis that an internal annuloplasty device, creating a completely symmetric post-repair BAV geometry, achieves superior aortic valve repair outcomes compared to external annuloplasty. If our hypothesis is confirmed, our study will significantly influence aortic valve repair practice and contribute to the refinement of guideline recommendations in the management of BAV patients with AR.
Trial Details
NCT Number NCT06869954
Lead Sponsor University Hospital Augsburg
Collaborators: Universitätsklinikum Hamburg-Eppendorf, University Clinic Frankfurt, Heart Center Leipzig - University Hospital
Conditions
(from sponsor)
Bicuspid Aortic Valve (BAV), Aortic Regurgitation Disease
Related terms Aortic Valve Insufficiency, Bicuspid Aortic Valve Disease
Enrollment 100 participants