Track this trial free. DataLookout checks ClinicalTrials.gov daily and emails you which fields changed on NCT05498376 (status, enrollment, completion dates, endpoints, sites) when this record is updated. Free accounts track up to 5 trials.

Track this trial

The Leadless AV Versus DDD Pacing Study

Study acronym: LEAVE DDD
StatusActive, Not Recruiting
PhasePhase 4
Started
View on ClinicalTrials.gov ↗

Record History

  1. Minor Trial status changed: Recruiting → Active, Not Recruiting
    • Site details revised
    v7
  2. Minor Re-verified, no change to tracked fieldsv6
  3. Notable Primary completion date: Dec 31, 2025 to Dec 31, 2026
    • Study completion date: Feb 28, 2026 to Dec 31, 2027
    v5
  4. Notable Primary completion date: May 31, 2024 to Dec 31, 2025v4
  5. Minor Re-verified, no change to tracked fieldsv3
  6. Notable Trial status: Not Yet Recruiting to Recruiting
    • Start date changed from estimate of Sep 1, 2022 to Aug 23, 2022
    • Site details revised
    v2
  7. Minor Study First Submitted
  • Stopped: an ongoing trial was terminated, suspended or withdrawn.
  • Notable: the trial’s plan changed such as a big move in its timeline or size, a new primary endpoint, sponsor or phase, or recruiting opened or resumed.
  • Minor: routine progress and housekeeping, such as sites added or enrollment closed.
Cardiac pacemaker (PM) implantation is the established treatment for relevant bradyarrhythmias. Conventional PMs require 1-3 pacing leads to register the heart's intrinsic activity ("sensing") and to deliver the electrical stimuli to the heart ("pacing"). These leads are responsible for the vast majority of morbidity after implantation and PM failures. Therefore, a leadless PM system (Micra TPS™, Medtronic, United States) has been introduced a few years ago. This system overcomes the limitations of leads, however, the first generation of the Micra TPS™ only allowed sensing and pacing in the right ventricle. More recently, an upgraded version has been introduced and gained market approval (Micra AV, Medtronic, United States). According to published results from several clinical trials, this device allows sensing the atrial activity and, thus, timing the delivery of the ventricular pacing impulse in a physiological manner similar to a conventional dual-chamber PM with two leads. Clinical feasibility and safety for this concept have been established already. However, it is unclear if this translates into a direct clinical benefit for patients in comparison to conventional PM systems. The aim of this trial is to compare the therapeutic efficacy of the Micra AV™ PM and conventional dual-chamber PM systems in patients with intermittent or permanent atrioventricular conduction block and a PM indication according to the latest European guidelines. Thus, patients will be randomized to either a conventional dual-chamber PM implantation or the implantation of a leadless Micra AV™ system. Patients will be stratified for gender (female/male) and a priori estimated physical exercise capacity ("fit"/"unfit"). The primary outcome will be the physical exercise capacity of the patients. The null hypothesis with regards to the primary endpoint is that the leadless pacemaker arm shows an inferior VO2 anaerobic threshold than the conventional pacemaker arm. Hence the alternative hypothesis postulates that the leadless pacemaker arm shows a non-inferior VO2 anaerobic threshold compared to the conventional pacemaker arm. Rejection of the null hypothesis is needed to conclude non-inferiority.
Trial Details
NCT Number NCT05498376
Lead Sponsor Insel Gruppe AG, University Hospital Bern
Collaborators: University of Bern
Conditions
(from sponsor)
Cardiac Pacemaker, Arrhythmias, Cardiac, Heart Diseases, Cardiovascular Diseases
Related terms Arrhythmias, Cardiac, Atrioventricular Block, Bradycardia, Cardiovascular Diseases, Heart Diseases
Enrollment 100 participants
Start Date
Primary Completion (estimated)
Study Completion (estimated)
Updated on ClinicalTrials.gov