Skip to content
DataLookout
Menu

NCT07770178

Safety, Tolerability, and Accuracy of a Hydrogel-Based Wearable Dynamic Intraocular Pressure Sensor in Healthy Adults

StatusRecruiting
PhaseNot applicable
Primary completion (estimated)
Track this trial

Free. We email you which fields changed when ClinicalTrials.gov updates this record.

Record History

All 2 versions: 2 with changes below. See every version on ClinicalTrials.gov ↗

  1. Notable Recruitment opened Show 4 more changesShow less
    • Eligibility criteria expanded, about 8 words
    • Start date changed from estimate of Aug 30, 2026 to Jul 22, 2026
    • Secondary endpoints: details revised at 4 of 6 entries
    • Site details revised
  2. Study First Submitted
  • Notable: the plan changed

Endpoints

Primary

Absolute Error of CLS-Predicted Intraocular Pressure Compared With Goldmann Applanation Tonometry
Timeframe: Day 1, at the third validation measurement

Secondary (6)

Agreement Between CLS-Predicted Intraocular Pressure and Non-Contact Tonometry
Increased incidence of corneal fluorescent staining grade
Conjunctival congestion score
Change From Baseline in Tear Break-Up Time After CLS Wear
Change From Baseline in Best-Corrected Visual Acuity After CLS Wear
Show 1 moreShow less
CLDEQ-8-Based Immediate Ocular Tolerability Questionnaire

Arms and interventions

Hydrogel-Based Wearable Dynamic Intraocular Pressure SensorExperimental

Participants will undergo a single-arm evaluation of a hydrogel-based wearable dynamic intraocular pressure sensor (CLS). After 2 hours of fasting from food and water, baseline ocular safety examinations will be performed. Intraocular pressure will first be measured using non-contact tonometry (NCT) and Goldmann applanation tonometry (GAT). Participants will then wear the CLS and undergo a 10-minute adaptation period before the first sensor signal is recorded. Participants will drink 1 L of water within 5 minutes. At 10-15 minutes after completion of water intake, a second sensor signal will be recorded, followed by CLS removal and repeat GAT and NCT measurements. After an interval of at least 45 minutes, NCT and GAT will be repeated, the CLS will be worn again for a 10-minute adaptation period, and a third sensor signal will be recorded. After completion of the measurement procedure, the CLS will be removed and ocular safety examinations will be repeated to evaluate changes associate

Devices: Hydrogel-Based Wearable Dynamic Intraocular Pressure Sensor

Sites

1 site in 1 country

  • Shanghai General HospitalShanghai, Shanghai Municipality, China