NCT07662304

Effect of Continuous Supraglottic Oxygen Insufflation Via Video Laryngoscope Blade on Apneic Oxygenation During Tracheal Intubation Under General Anesthesia

StatusNot Yet Recruiting
PhaseNot applicable
Primary completion (estimated)

At risk: Primary completion moved at least 3 years later.

Track this trial

Free. We email you which fields changed when ClinicalTrials.gov updates this record.

Record History

All 2 versions: 2 with changes below. See every version on ClinicalTrials.gov ↗

  1. Notable Primary completion pushed from Jun 22, 2026 to Jul 1, 2029
    • Start date: Jun 22, 2026 to Nov 14, 2026
    • Eligibility criteria expanded, about 6 words
    • Study completion date: Jun 22, 2029 to Jul 1, 2029
  2. Study First Submitted
  • Notable: the plan changed

Endpoints

Primary

arterial partial pressure of oxygen (PaO2) at 3 min
Timeframe: 3 minutes after intubation

Secondary (6)

PaO2 at before preoxygenation
PaO2 at 1 minutes when intubation criteria are met
PaO2 at 2 minute when intubation criteria are met
PaO2 at 5 minutes when intubation criteria are met
PaCO2 changes during apnoea
Show 1 moreShow less
all complicatios at 24 hours postoperatively.

Arms and interventions

control group (Group C)Active comparator

Before surgery, all participants received a radial arterial line. Participants were then placed supine, in a 10 degrees reverse Trendelenburg position. Preoxygenation was then performed using atight fitting face mask and having Tracheal intubation was thereafter performed using a video laryngoscopewhen the anaesthetist assessed the conditions as appropriate in the control group (Group C).The correct placement of the tracheal tube was confirmed visually by the anaesthetist in charge and a member of the study team. The tracheal tube was secured, and the participant was left apnoeic with the tracheal tube open to the atmosphere until the peripheral oxygen saturation declined to 93% or apnoea is sustained for 5 minutes.

The continuous laryngeal oxygen supply group (Group B)Experimental

The continuous laryngeal oxygen supply group (Group B) used the same preoxygenation and anesthesia induction methods as the control group. When intubation conditions were assessed to be met, laryngoscopy was performed to evaluate the airway. If the laryngoscopic view was Cormack and Lehane grade 3 or grade 4, the subject was excluded from the study and tracheal intubation was performed. Otherwise, continuous laryngeal oxygen supply was initiated through a modified disposable video laryngoscope blade, which has an internal lumen. The distal end of the blade is connected to an oxygen delivery tube, and the other end of the oxygen delivery tube is connected to a flowmeter, with an oxygen flow rate of 10 L/min to maintain a continuous oxygen supply to the larynx. During apnoea, anaesthesia was maintained with intermittent boluses of propofol and, if necessary, either infusion of remifentanil. Upon reaching an SpO2 of 93% or apnoea is sustained for 5 minutes, tracheal intubation and mechan

Procedures: control group (Group C)

Devices: The continuous laryngeal oxygen supply group (Group B)