Track this trial free. DataLookout checks ClinicalTrials.gov daily and emails you which fields changed on NCT06692218 (status, enrollment, completion dates, endpoints, sites) when this record is updated. Free accounts track up to 5 trials.

Track this trial

Leadless Pacemaker Implantation Positions and Its Relationship with Procedure Efficacy and Complication

StatusUnknown
PhaseNot applicable
Started
View on ClinicalTrials.gov ↗
Record status
This record was last updated November 18, 2024 (before its estimated September 30, 2025 completion). Its status may not reflect the trial's current state.

Record History

  1. Minor Changed Registry marked status Unknown (sponsor has not verified the record since Sep 2024); last known: Recruiting
  2. Minor Study First Submitted
  • Stopped: an ongoing trial was terminated, suspended or withdrawn.
  • Notable: the trial’s plan changed such as a big move in its timeline or size, a new primary endpoint, sponsor or phase, or recruiting opened or resumed.
  • Minor: routine progress and housekeeping, such as sites added or enrollment closed.
Leadless pacemakers (LP) are safe and effective alternatives to transvenous pacemakers in select patients. Advances in battery and electronics technology allow for the entire pacemaker system to be implanted into the right ventricle, bypassing many of the weaknesses of transvenous pacemakers. Traditionally leadless pacemakers have been implanted in the right ventricular (RV) septum to prevent cardiac perforation, and much emphasis is placed during implantation to ensure a septal implant. However, in Asians with smaller heart sizes, septal implantation may be unfeasible. Cases of RV free wall implant have been achieved without any complications. This study aims to examine patients previously implanted with LP and determine their final attachment location. If a substantial portion of complication-free patients had RV free wall implants, then it can be argued the additional effort to ensure a septal implant is unnecessary. Additionally, intraoperative data, such as the intracardiac electrogram, may contain parameters correlated with implant position. This study also aims to study this correlation to guide future implant procedures. This is a prospective-retrospective cohort study. Patients who will implant leadless pacemakers or already implanted leadless pacemakers since 1 Jan 2015 will be recruited. After the implantation, patients will be invited back for a noncontrast ECG-gated CT heart. It will be timed at the end diastole and a 3D reconstruction will be performed. The attachment of the leadless pacemaker to the RV will be adjudicated from the CT. The patients' pre-operative laboratory tests, baseline demographics, medical history, LP electrical data and pre- and post-operative medication regiment will be collected retrospectively from their medical records in the Hospital Authority's Clinical Management System (CMS) and Clinical Data Analysis and Reporting System (CDARS).
Trial Details
NCT Number NCT06692218
Lead Sponsor Chinese University of Hong Kong
Conditions Leadless Pacemaker
Enrollment 196 participants
Start Date
Primary Completion (estimated)
Study Completion (estimated)
Updated on ClinicalTrials.gov