Clinical Trial

A Randomised Control Clinical Trial Investigating the Effect of H-PRF on Implant Stability and Marginal Bone Levels

Recruiting
View on ClinicalTrials.gov →
Record status
This record was last updated June 11, 2024 (before its estimated June 1, 2026 completion). Its status may not reflect the trial's current state.
Summary
This research will be a randomised controlled trial (RCT) investigating whether the use of Horizontal Platelet Rich Fibrin (H-PRF) increases implant stability compared to those implants placed without H-PRF, and therefore, contributes to the implant's overall success. H-PRF is a second generation platelet concentrate that consists of a fibrin mesh containing cytokines and leukocytes. It has been shown to stimulate mesenchymal stem cells and osteoblasts that encourage bone formation as a result of the growth factors released from platelets, which should aid in osseointegration of implants. There is limited research that investigates the effects of H-PRF on implant stability. There is, however, some evidence that platelet-rich fibrin (PRF), which is produced in a fixed-angle centrifuge, increases implant stability and H-PRF is considered the evolution of PRF products. This research would follow a H-PRF preparation protocol which involves taking a sample of venous blood from patients using a butterfly needle to collect up to 8-9ml tubes of blood. After the tube of blood is collected, it would immediately be placed in a horizontal centrifuge machine with 3 tubes of water to balance the centrifuge, and placed opposite each other. A set rpm and time will be chosen, and the centrifuge will run until the time is complete. The H-PRF clots would then be ready and taken out of the tubes to separate them from the red blood cells. Following randomisation, implants will be placed in the upper or lower jaws of patients attending the Dublin Dental University Hospital using the standard implant protocol. Half of the implants will be coated with H-PRF, the other half (control group) would be placed without HPRF. Implant stability and marginal bone levels will be measured at three different stages: 1) Initial implant placement, 2) Second stage surgery when the implant is uncovered after healing and integrated with the bone, 3) When the definitive crown or bridge is attached to the implant. Insertion torque at baseline will also be measured. The above results will be collected and assessed to determine the effects of H-PRF, if any, on implant stability and the preservation of bone levels around implants.
Trial Details
NCT Number NCT06453330
Lead Sponsor University of Dublin, Trinity College
Conditions Osseointegration Failure of Dental Implant
Enrollment 50 participants
Start Date 2024-05-17
Primary Completion 2026-06-01 (estimated)
Study Completion 2026-09-01 (estimated)
Updated on ClinicalTrials.gov 2024-06-11