- Minor Study completion pushed from Jul 1, 2026 to Jul 1, 2027
- Minor Study completion date: Jun 29, 2025 to Jul 1, 2026v9
- Minor Study completion date: Jun 29, 2024 to Jun 29, 2025v8
Minor Trial status: Recruiting to Active, Not Recruitingv7 Show 4 more changesShow less
- Enrollment target: estimated 125 to confirmed 121
- Primary completion date changed from estimate of Jun 29, 2023 to Apr 26, 2023
- Study completion date: Jun 29, 2023 to Jun 29, 2024
- Site details revised at 3 of 3 sites
- Minor Study sites: 1 to 3v5
Show 3 earlier versionsHide 3 earlier versions
- Minor Site contact updatedv4
- Minor Interventions: Acute Intermitted Hypoxia (Device), Massed Practise (Procedure), Rapael Glove (Device) to Acute Intermitted Hypoxia (Other), Massed Practise (Procedure), Rapael Glove (Other)v3
- Notable Eligibility criteria expanded, about 42 words
- Site contact updated
- Study First Submitted
- Notable: the plan changed
- Minor: routine updates
Endpoints
Primary
Arms and interventions
Seek to address gross upper extremity movements, grip and pinch strength, and coordination.The ultimate goal of the session is to achieve a total of 300 repetitions during training. Once fitted with the mask, initial recordings of heart rate, blood pressure, and arterial oxygen saturation (SpO2) will be taken. The sequence of hypoxia will consist of 60- 90 seconds of 9-10% O2 (FiO2 0.09), alternating with 60- 90 seconds of 21% O2 (normoxic air FiO2 0.21). The delivery of hypoxia and normoxic air mixtures will be repeated up to 18 times per session each, for a total of up to 45 minutes, to maintain SpO2 at 80-90%.
Seek to address gross upper extremity movements, grip and pinch strength, and coordination.The ultimate goal of the session is to achieve a total of 300 repetitions during training. Once fitted with the mask, initial recordings of heart rate, blood pressure, and arterial oxygen saturation (SpO2) will be taken. The sequence of hypoxia will consist of 60- 90 seconds of 9-10% O2 (FiO2 0.09), alternating with 60- 90 seconds of 21% O2 (normoxic air FiO2 0.21). The delivery of hypoxia and normoxic air mixtures will be repeated up to 18 times per session each, for a total of up to 45 minutes, to maintain SpO2 at 80-90%.
The Rapael Smart Glove is a virtual reality hand exoskeleton rehabilitation device. The tasks selected will address gross movement, hand function, and dexterity. Tasks utilized will include, but are not limited to: fly swat, throwing darts, squeezing an orange, catching a baseball, and floating fish. The number of total repetitions and activity outcomes will be recorded. Once fitted with the mask, initial recordings of heart rate, blood pressure, and arterial oxygen saturation (SpO2) will be taken. The sequence of hypoxia will consist of 60- 90 seconds of 9-10% O2 (FiO2 0.09), alternating with 60- 90 seconds of 21% O2 (normoxic air FiO2 0.21). The delivery of hypoxia and normoxic air mixtures will be repeated up to 18 times per session each, for a total of up to 45 minutes, to maintain SpO2 at 80-90%.
The Rapael Smart Glove is a virtual reality hand exoskeleton rehabilitation device. The tasks selected will address gross movement, hand function, and dexterity. Tasks utilized will include, but are not limited to: fly swat, throwing darts, squeezing an orange, catching a baseball, and floating fish. The number of total repetitions and activity outcomes will be recorded. Once fitted with the mask, initial recordings of heart rate, blood pressure, and arterial oxygen saturation (SpO2) will be taken. The sequence of hypoxia will consist of 60- 90 seconds of 9-10% O2 (FiO2 0.09), alternating with 60- 90 seconds of 21% O2 (normoxic air FiO2 0.21). The delivery of hypoxia and normoxic air mixtures will be repeated up to 18 times per session each, for a total of up to 45 minutes, to maintain SpO2 at 80-90%.
Once fitted with the mask, initial recordings of heart rate, blood pressure, and arterial oxygen saturation (SpO2) will be taken. The sequence of hypoxia will consist of 60- 90 seconds of 9-10% O2 (FiO2 0.09), alternating with 60- 90 seconds of 21% O2 (normoxic air FiO2 0.21). The delivery of hypoxia and normoxic air mixtures will be repeated up to 18 times per session each, for a total of up to 45 minutes, to maintain SpO2 at 80-90%. Hearth rate and pulse oximetry will be continuously monitored throughout, and recording will be taken at each alteration in sequence. Blood pressure will be taken upon completion of the total sequence
Other: Acute Intermitted Hypoxia, Rapael Glove
Procedures: Massed Practise
Sites