Skip to content
DataLookout
Menu

NCT06662630

Physiological Effects and Safety of Continuous High-frequency Oscillatory Ventilation in Mechanical Ventilation Patients

StatusUnknown
PhaseNot applicable
Primary completion (estimated)
Track this trial

Free. We email you which fields changed when ClinicalTrials.gov updates this record.

Record History

All 2 versions: 2 with changes below.

  1. Minor Changed Registry marked status Unknown (sponsor has not verified the record since Oct 2024); last known: Recruiting
  2. Notable Trial status: Not Yet Recruiting to Recruiting
    • Study sites: 0 to 1
    • Start date: Nov 1, 2024 to Nov 19, 2024
    v2
  3. Study First Submitted
  • Notable: the plan changed
  • Minor: routine updates

Endpoints

Primary

EELV
Timeframe: Baseline, and at the end of intervention (30th minute)
EIT
Timeframe: Baseline, and at the end of intervention (30th minute)

Secondary (5)

Central venous pressure before and after the CHOF treatment
PaO2/FiO2 ratio before and after the CHOF treatment
Plateau pressure
Mean arterial pressure
Adverse events

Arms and interventions

CHFO groupExperimental

After checking the availability of the CHFO machine (MetaNeb® system), the inclusion and non-inclusion criteria, the patient is included. The following procedures are performed: 1. installation of an EIT belt in the 4th or 5th intercostal space (Pulmovista® 500, Dräger) 2. continuous recording of digital and analogic data After collecting initial data from the patient within 30 minutes before CHFO treatment, successive 10-minutes CHFO were performed. At the end of the treatment, all the data is collected.

Devices: High-Frequency Oscillatory Ventilation

Sites

1 site in 1 country

  • Zhongshan Hospital, Fudan UniversityShanghai, Shanghai Municipality, China